Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T01CM00778
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/15/2001 | FRAMING | Approved | IVRS - Inspection 0000* | |
05/14/2001 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) ITEMS 2, 3, 5 AND 11 FROM 5/11/01 NOT COMPLIED WITH | |
05/11/2001 | FRAMING | Denied | 1) BOND GAS LINE 2) STAIR STRINGERS NOT PROPERLY SUPPORTED-SCE 4/SD3 3) FIRE/DRAFT STOP STAIRS 4) HEADERS FOR 2030 WINDOWS MUST BEAR ON TRIMMERS SHIM ALL TRIMMERS 5) ELECTRIC OUTLETS AND WIRE NOT ALLOWED IN RETURN AIR 6) MASTER BEDROOM 5040 WINDOW WALL NOT NAILED AT PLATE 7) MASTER BEDROOM TUB LEAK 8) BEARING STUD BY STAIR AND LAV 2ND FLOOR-REQUIRES ADDED STUD 9) F/B LOFT/ENTRY CEILING SOUTH WALL 10) WATER HEATER VALVE LEAK 11) LAUNDRY #2 S/W FURRING NAIL AT 4" ON CENTER AND PROVIDE TOP BLOCK 12) WIRE BELOW CEILINGS 13) KITCHEN GAS/ELECTRIC BOXES NOT SECURE |