Permit: T01CM00757

Parcel: 134221010


Addresses:

6802 E COOPER ST

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
10/02/2001 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000*
04/03/2001 PLUMBING - INTERMEDIATE Not ready for Inspection IVRS - Inspection 0000*/1. NEED 3/4" GAS LINE TO FURNACE, DON'T RUN. 2. GAS LINE THRU RETURN PLENIUM INSTALL SO YOU CAN REMOVE FURNACE, WITHOUT DISCONNECTING PIPE. 3. 6" CLR TO FURN. FLUE WITH WIRS BO PLASTIC H20 LINE, USE A B-VENT DBL JACKET TO REDUCE CLR. TO 1" COMBUSTIBLE, MOVE POLY H20 LINE AWAY FROM FURN. FLUE, INSTALL FIRE BLOCKS.