Permit: T01CM00683

Parcel: 137336830


Addresses:

6241 S MANUS PL

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
04/17/2001 FRAMING Approved IVRS - Inspection 0000*
04/10/2001 FRAMING Denied DRYER VENT CANNOT HAVE MESH COVERED T CAP, NO PRESSURE TEST ON GAS, FURNACE DUCT RESTRICTED BED ROOM 2 SUPPORT THROUGHOUT, HEADERS MUST BEAR ON TRIMMERS, HTT22 HOLD DOWN NUTS LOOSE, NO COT APP TRUSS DRAWINGS, MECHANICAL DUCT DEFUSER LOCATION AND SIZES NOT PER PLAN
04/05/2001 FRAMING Denied 1. GABLE END NOT SECURED TO DBL TOP PLATE. 2. PROVIDE C.O.T. APPROVED TRUSS CALC'S. 3. ELECT. BOXES NOT SECURE PROTECT ROMEX CABLE THRU OUT. 4. SHEAR TRANSFER NOT NAILED PER PLAN THRU OUT. 5. FHA STRAPS MISSING THRU OUT. 6. DAMPERS MISSING AT EXHAUST FANS. 7. RETURN AIR GRILL NOT SIZED PER PLAN.