Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T01CM00681
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/18/2001 | FRAMING | Approved | IVRS - Inspection 0000* | |
| 04/17/2001 | FRAMING | Denied | IVRS - Inspection 0999*/1) PROTECT ELEC ROMEX CABLE THRU OUT PROVIDE BOXES FOR ALL LIGHT FIXTURES 2) VENT TO ROOF NOT CONNECTED OR SUPPORTED 2ND POSTINELY SUPPORT ALL DRAIN LINES NO P TAPE 3) SECURE CLOSET FLANGE AT 2ND FLOOR 4) VACUMN LINES NOT SECURE AS PER MANF SPEC'S AND NOT PROTECTED THRU OUT 5) AC LINES OUT OF WALL FLUE PIPES IN DIRECT CONTACT WITH COMB MAT 6) EXTEND PLATFORM RE-INSP FEE REQ'D FOR MECH INSPECTION 7) PROVIDE EXHAUST OUTLET FOR VACUMN TO OUTSIDE | |
| 04/13/2001 | FRAMING | Denied | IVRS - Inspection 0999*/1) SECURE WATER LINES TO CENTER OF STUD OR PROTECT 2) FAA DBL TOP PLATES AT OVER BORES 3) POST TO BEAM CONNECTIONS 4) PROTECT ELEC WITHIN 1 1/4 FROM STUD 5) SUPPORT 90 DEGREE WITH AN APPROVED METHOD 6) REFRIGERENT LINES OUTSIDE OF WALL 7) DRYER VENT NOT COMPLETE 8) FLOOR SHEATHIN NOT SECURED ROOF NOT DRIED IN FROM COMBUSTIBLE MATERIAL PROVIDE CLEARANCE 9) FLUE PIPES FOR FURNACE |