Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 09/19/2002 |
ELECTRIC - FINAL |
|
Approved |
|
| 09/16/2002 |
ELECTRIC - FINAL |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) USE A GROUND WIRE FOR SUB-PANEL TO BE IN SAME RACEWAY AS FEEDERS 2) USE ONLY MURRAY BRAND BREAKERS IN PANEL 3) BOND WATER LINE 4) SECURE COOLER MID-WEST BOX TO WALL 5) PLEASE LEAVE ALL PAPER WORK FROM PREVIOUS INSPECTIONS ON SITE WITH PERMIT CARD 6) NEED DIA ELECTRIC UNIONS OR BRASS, FITTINGS AT COPPER TO IRON WATER LINES REAR PORCH 7) 3 WATER FIXTURES, COLD SIDE WITH ONLY 1/2" PIPE TO BATHROOM 8) NOT READY NO ONE HOME |
| 08/13/2002 |
ELECTRIC - FINAL |
|
Not ready for Inspection |
NOT READY FOR INSPECTION |
| 06/27/2002 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) POST ADDRESS ON STUCTURE 3" NUMBERS 2) PROVIDE ANTI-SIPHON DEVICES AT HOSE BIBS 3) PLUMBING NOT PROPERLY VENTED 4) INSTALL CLOSET RING AND PROVIDE VENT 5) SECURE WIRES AT DOOR BELL TRANSFORMER 6) CAP OFF GAS LINE SHUT OFF VALVE AT HALL CLOSET 7) SECURE EVAP COOLER PROPERLY 8) PROVIDE FUSE STRUCTURE AT COOLER RECEPTACLE PER CODE |
| 07/09/2001 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) WORK NOT COMPLETE FOR FINALS |
| 05/01/2001 |
ELECTRIC - FINAL |
|
Denied |
1) GRD WIRE AT BOXES SECURE TO GRD SCREW 2) SD AT BD RM REQ'S 3' DISTANCE FROM VENT 3) SECURE FLUE AT FURNACE 4) ROMEX TOUCHING FLUE AT FURNACE 5) FURNACE REQ'S HIGH AND LOW COMBUSTION AIR RELIEF 6) METAL BOXES REQUIRE PROPER GRD SCREW 7) WIRING METHOD AT BACK BD RM IN ATTIC ABOVE EXTENSION SUB STANDARD CONNECTING ROMEX WITH OLD WIRING NOT PER CODE |
| 04/19/2001 |
ELECTRIC - FINAL |
|
Denied |
1) PROVIDE 1" CLEARANCE AT WATER HEATER FLU PIPE 2) IDENTIFY ALL BREAKERS AT PANEL |
| 03/26/2001 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0999* |