Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 06/15/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 06/12/2001 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) SECURE VERTICAL GAS LINE AT WATER HEATER 2) ALL TOP PLATES, BOTTOM PLATES AND LEDGERS (ON BEARING WALLS) MUST HAVE FHA STRAPS NOT BANG PLATES 3) SUPPORT 90 DEGREE VENT ELBOWS IN MASTER BATH-2 4) NEED PRESSURE TEST ON GAS LINES 5) PLAN CHANGES NEED TO BE OK'D BY CITY OF TUCSON FOR HOT WATER HEATER, HVAC DISTRIBUTION, DOOR AND WINDOW CHANGE |
| 06/07/2001 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) PEX LINE, DON'T ATTACH TO ROOF DECK 2) REAR DOOR ADD ANCHOR BOLT STRAIGHTEN BOTTOM PLATE 3) INSTALL ALL FLASHING, PREP SHOWER PAN 4) NEW PANTRY 4 SQUARE BOX WIRE NUT BOTH WIRES 5) SECURE WALL AT DRYER DUCT STRAP AT TOP PLATE BOTH SIDES 6) MINIMUM LENGTH WASHER STAND PIPE 18" ABOVE TOP OF HORIZONTAL TRAP ARM, NEED TO RE-VENT LAUNDRY TUB, GO BACK TO DRAIN SECTION VERTICAL PIPE USE Y OR COMBO, TRAP ARTM TO BE SAME SIZE AS TRAP, PIPES OUT OF WALL LAUNDRY ROOM, YOU MAY NEED TO FURR OUT, BANG PLATE WHERE NEEDED 7) OUTLET NOT SECURED ENTRY OLD TO NEW ADDITION 8) SECURE GASLINE AT EXTERIOR WALL 9) STUCCO LATH TO EXTEND BELOW BOTTOM PLATE PER ICBO REPORT 10) TAPE WIRE SPLICE IN CIELING NEXT OLD STRUCTURE NOTE: CAN WET VENT LAUNDRY TUB TRAP ARM MUST BE 1/2" MAXIMUM 42" 11) PUT CLEANOUT ON VERTICAL SECTION |