Inspection Status: Approved
Inspection History: ELECTRIC - INTERMEDIATE
| Date |
Description |
Inspector |
Results |
Comments |
| 05/23/2001 |
ELECTRIC - INTERMEDIATE |
|
Approved |
IVRS - Inspection 0000*1)NEED TO INSTALL CANS.2)NEED TO INSTALL CAN IN HALLWAY.3)NEED TO INSTALL CANS IN LIVING ROOM.4)NEED ILUMINATION IN CLOSET WITH PANEL 110-26 (2)(D). |
| 05/17/2001 |
ELECTRIC - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection 0000*PARTIAL, OK 1ST FLOOR. |
| 05/15/2001 |
ELECTRIC - INTERMEDIATE |
|
Partial Approval |
IVRS - Inspection 0000* |
| 05/08/2001 |
ELECTRIC - INTERMEDIATE |
|
Denied |
IVRS - Inspection 0999* 1) INSTALL FLEX FOR WATER HEATERS AT ROUGH ELEC. 2) PLEASE INSTALL GROUND TAILS AT ROUGH ELEC. 3) NEED STRAIN RELIEF CONNECTORS AT PANEL 373-5(C) 6) SECURE NM CABLES AS PER CODE 7) HOOD NOT TO BE ON KITCHEN APPLIANCE CIRCUIT 210-23(A) 8) BATH LIGHT TO HAVE BOX |