Inspection Status: Approved
Inspection History: PLUMBING - ROUGH, SOIL
| Date |
Description |
Inspector |
Results |
Comments |
| 11/08/2001 |
PLUMBING - ROUGH, SOIL |
|
Approved |
IVRS - Inspection 0000* |
| 11/05/2001 |
PLUMBING - ROUGH, SOIL |
|
Partial Approval |
IVRS - Inspection 0000*1.) REPLUMB FRONT BATH ROOM PER DETAIL LEFT ON SITE, LEAVE DETAIL FOR NEXT INSPECTOR. |
| 11/02/2001 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999*/ 1) ALL WATER CLOSETS IMPROPERLY VENTED SEE UPC SECTION 905.2 2) NEXT FAILURE MAYBE CHARGED A RE-INSPECTION FEE |
| 10/23/2001 |
PLUMBING - ROUGH, SOIL |
|
Denied |
IVRS - Inspection 0999*/ 1) ROUGH PLUMBING MUST HAVE A 10 FOOT HIGH WATER COLUMN TEST 2) SANITARY "T" FITTINGS ARE NOT ALLOWED TO BE INSTALLED IN HORIZONTAL DRAINS 3) HORIZONTAL BENDS MUST BE MADE WITH LONG SWEEP FITTINGS 4) CHANGES IN DIRECTION FROM VERTICAL TO HORIZONTAL MUST BE WITH LONG SWEEP FITTINGS NOT VENT 90'S |