Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
| Date |
Description |
Inspector |
Results |
Comments |
| 09/14/2001 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Approved |
IVRS - Inspection 0000* |
| 09/07/2001 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Denied |
IVRS - Inspection 0999*/ 1) REINFORCING STEEL CANNOT BE IN CONTACT WITH SOIL. ISOLATE ALL HORIZONTAL STEEL FROM REBAR STAKES IN SOIL 2) UFER GROUND CLAMPS LOOSE ON REBAR 3) 3 INCHES CLEARANCE REQUIRED BETWEEN REBAR AND SOIL-MANY AREAS IN CONTACT 4) PLAN CALLS FOR HPA HD22 HOLDOWNS HSA3522 INSTALLED. PROVIDE PROOF OF EQUALITY |
| 08/08/2001 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) NORTH AND WEST WALL OK, AREA MARKED ON PLAN PAGE 2 |