Permit: T01CM00590

Parcel: 141085320

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T01CM00590

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
07/23/2001 PLUMBING - FINAL Approved 1.) ALL CORRECTION MADE OK 2.) PLUMBING FINAL OK 3.) OK FOR C OF O PENDING ANY OTHER INSPECTIONS AND VERIFICATION OF CERTIFICATION OF RPBP.
07/19/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) 15" MIMIMUM FROM SIDE WALL OR OBSTRUCTION TO CENTER ON WC. 2.) MINIMUM 15" FROM SIDE WALL OR OBSTRUCTION TO CENTERLINE OF HC URINAL 3.) RPBP TESTED AND APPROVED.
07/17/2001 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*1.) NOT READY FOR INSPECTION.
07/15/2001 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) HC WC NOT INSTALLED PER PLAN 2.) HC URINAL NOT INSTALLED PER PLAN 17" MAX ELERATION 6" MIN CRITICAL LEVEL TO TOP OF URINAL OR W.C. 3.) LAVATORIES (HC NOT INSULATED. 4.) CHECK ELEVATION OF EWC AGAINST DETAIL 5.) EXPANSION TANK TO BE SUPPORTED 6.) JANITORS SINK NOT SECURE TO WALL, NOT CAULKED 7.) 15" MINIMUM FROM SIDEWALL TO CEATER FOR W.C. 8.) PLEASE HAVE PLUMBER CHECK ALL WORK.
06/29/2001 PLUMBING - FINAL Partial Approval IVRS - Inspection 0000*OK FOR TEMP C OF O