Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 12/13/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 12/11/2001 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) BUILDING IS INSULATED |
| 12/03/2001 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) LIGHT CANS IN CLOSETS TOO BE 18 1/2" OFF BACK WALL, 6" AWAY FROM 12" SHELF 2) PROTECT ALL PIPES FROM DRYWALL SCREWS 3) CONNECT ROMEX TO EXHAUST FAN (BATHROOM) THRU THE KNOCKOUT 4) YOU NEED ONE BEDROOM EGRESS WINDOW TO COMPLY WITH EMERGENCY EGRESS REQUIRMENTS 5) NEED TO SEE A DETAIL ON BEARING HEADER BEAM (METAL) KITCHEN-DINNING CEILING JOIST 6) GAS PRESSURE TEST OK |
| 11/07/2001 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) OK TO COVER ROOF SHEATHIN |