Permit: T01CM00578

Parcel: 126170150


Addresses:

4131 E PASEO DORADO

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
12/13/2001 FRAMING Approved IVRS - Inspection 0000*
12/11/2001 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) BUILDING IS INSULATED
12/03/2001 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) LIGHT CANS IN CLOSETS TOO BE 18 1/2" OFF BACK WALL, 6" AWAY FROM 12" SHELF 2) PROTECT ALL PIPES FROM DRYWALL SCREWS 3) CONNECT ROMEX TO EXHAUST FAN (BATHROOM) THRU THE KNOCKOUT 4) YOU NEED ONE BEDROOM EGRESS WINDOW TO COMPLY WITH EMERGENCY EGRESS REQUIRMENTS 5) NEED TO SEE A DETAIL ON BEARING HEADER BEAM (METAL) KITCHEN-DINNING CEILING JOIST 6) GAS PRESSURE TEST OK
11/07/2001 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) OK TO COVER ROOF SHEATHIN