Permit: T01CM00573

Parcel: 137337260


Addresses:

1600 W JOYCE LOU DR

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
03/22/2001 FRAMING Approved IVRS - Inspection 0000*
03/21/2001 FRAMING Partial Approval IVRS - Inspection 0000*/1. REMOVE SCREEN DRYER VENT T TOP. 2. PROTECT DRYER VENT FROM NAIL PENETRATIONS. 3. REMOVE PAPER FROM HOT WATER FLUE PIPE. 4. PROVIDE CLEANOUT SCHEMATIC AND VENT SCHEMATIC AS NOTED PREVIOUSLY MAY REQUIRE CLEAN OUTS AT LAV'S OR TUB/SHOWER CANNOT VARIFY WITHOUT APPRV'D DOC'S. 5. EXHAUST FANS MISSING DAMPERS. 6. PVC CONDENSATION LINE, NOT COMPLETE. 7. MAKE UP ALL ELEC. ROMEX 8. PROVIDE DRAINAGE FITTINGS FOR HORIZONTAL VENT TO ROOF AT KITCHEN SINK.