Permit: T01CM00572

Parcel: 141113190

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T01CM00572

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
03/14/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
03/13/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/1. NO TRUSS DRAWINGS ON SITE. 2. HOLD DOWN BY ENTRY MISSED STUD. 3. HOLDOWN AT S.E. CORNER MISSED STUD. 4. HOLD DOWN AT S.W. CORNER ONLY HALF NAILED. 5. PORCH LEDGER NOT CLIPPED PER 8/SD2. 6. HOLD DOWN AT REAR CENTER OF HOUSE HALF NAILED. 7. TRUSS EXCESS OF 24" O.C. S.E. HIP. NO ACCESS TO SECOND FLOOR ROOF. YOU MUST PROVIDE LADDER.