Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
Permit Number - T01CM00561
Inspection Description - ELECTRIC - RECONNECT
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/07/2001 | ELECTRIC - RECONNECT | Approved | IVRS - Inspection 0000*/1. NEED ELECT CIRCUIT RUN FOR RANGE #8-3 WITH GROUND. 2. SERV. PANEL ALL BREAKERS TO BE SAME AS MIAN BREAKER (BRAND). | |
| 02/22/2001 | ELECTRIC - RECONNECT | Not ready for Inspection | IVRS - Inspection 0000*/1. NEED TWO GROUND RODS 6' APART #4 CU. CHECK WITH TEP FOR A RESTRAINING CLEVIS. 2. SECURE GAS LINE USE UNI STRUT. 3. EXTEND GAS LINES AT H20 AND FURNACE. 4. NEED RANGE CIRCUIT 5. BREAKERS NOT TO BE CHALLENGER TYPE 6. NEED GAS TEST 10 LB FOR 15 MIN. | |
| 02/06/2001 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection 0999*/1. SECURE BOND WIRE FROM WATER AND GAS LINE SECURED TO ELECTRIC PANEL NEUTRAL BAR. 2. IDENTIFY ALL CIRCUITS AT PANEL. 3. PROVIDE A PLUG UNDER PANEL AT CONCENTRIC KNOCK OUT. LEAVE ALL DOCUMENT'S FOR INSPECTION ON SITE IF POSSIBLE. |