Inspection Status: Approved
Inspection History: ELECTRIC - RECONNECT
| Date |
Description |
Inspector |
Results |
Comments |
| 03/07/2001 |
ELECTRIC - RECONNECT |
|
Approved |
IVRS - Inspection 0000*/1. NEED ELECT CIRCUIT RUN FOR RANGE #8-3 WITH GROUND. 2. SERV. PANEL ALL BREAKERS TO BE SAME AS MIAN BREAKER (BRAND). |
| 02/22/2001 |
ELECTRIC - RECONNECT |
|
Not ready for Inspection |
IVRS - Inspection 0000*/1. NEED TWO GROUND RODS 6' APART #4 CU. CHECK WITH TEP FOR A RESTRAINING CLEVIS. 2. SECURE GAS LINE USE UNI STRUT. 3. EXTEND GAS LINES AT H20 AND FURNACE. 4. NEED RANGE CIRCUIT 5. BREAKERS NOT TO BE CHALLENGER TYPE 6. NEED GAS TEST 10 LB FOR 15 MIN. |