Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T01CM00561

Parcel: 121110530

Inspection Status: Approved

Inspection History: ELECTRIC - RECONNECT

Permit Number - T01CM00561

Inspection Description - ELECTRIC - RECONNECT

Inspection Status - Approved

Date Description Inspector Results Comments
03/07/2001 ELECTRIC - RECONNECT Approved IVRS - Inspection 0000*/1. NEED ELECT CIRCUIT RUN FOR RANGE #8-3 WITH GROUND. 2. SERV. PANEL ALL BREAKERS TO BE SAME AS MIAN BREAKER (BRAND).
02/22/2001 ELECTRIC - RECONNECT Not ready for Inspection IVRS - Inspection 0000*/1. NEED TWO GROUND RODS 6' APART #4 CU. CHECK WITH TEP FOR A RESTRAINING CLEVIS. 2. SECURE GAS LINE USE UNI STRUT. 3. EXTEND GAS LINES AT H20 AND FURNACE. 4. NEED RANGE CIRCUIT 5. BREAKERS NOT TO BE CHALLENGER TYPE 6. NEED GAS TEST 10 LB FOR 15 MIN.
02/06/2001 ELECTRIC - RECONNECT Denied IVRS - Inspection 0999*/1. SECURE BOND WIRE FROM WATER AND GAS LINE SECURED TO ELECTRIC PANEL NEUTRAL BAR. 2. IDENTIFY ALL CIRCUITS AT PANEL. 3. PROVIDE A PLUG UNDER PANEL AT CONCENTRIC KNOCK OUT. LEAVE ALL DOCUMENT'S FOR INSPECTION ON SITE IF POSSIBLE.