Inspection Status: Approved
Inspection History: ROOF NAILING
Permit Number - T01CM00552
Inspection Description - ROOF NAILING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/14/2001 | ROOF NAILING | Approved | IVRS - Inspection 0000* | |
03/13/2001 | ROOF NAILING | Denied | IVRS - Inspection 0999*/O.S.B ROOF PANELS REQUIRE 1/8" END AND EDGE CLEARANCE TOO TIGHT. BUCKELING. 2. 2 EACH O.S.B. ROOF PANLES LOOSE. NOT NAILED OR HAVE SHINERS AND MUST SPAN 2 BAYS-3 TRUSSES. 4. NO TRUSS DRAWINGS ON SITE. 5. COVERED PATIO NOT CLIPPED PER 8/SD2. | |
03/12/2001 | ROOF NAILING | Denied | IVRS - Inspection 0999*/ONE ROW NOT NAILED ON ROOF PANEL OVER FRONT PICTURE WINDOW. | |
03/07/2001 | ROOF NAILING | Not ready for Inspection | IVRS - Inspection 0000* | |
03/06/2001 | ROOF NAILING | Denied | IVRS - Inspection 0950* |