Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T01CM00532

Parcel: 137338940


Addresses:

6293 S BEARDSLEE DR

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
03/22/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*/NOTE PROVIDE ALTERNATIVE HOLDOWN DEVICE AT 3 CAR GARAGE S WEST CORNER SEE SHEET S.1.1.
03/21/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/1. CHECK CLIPS AND STRAP THRU OUT. 2. CHECK SHEAR PANELS THRU OUT. 3. STAPLES AND SCREWS NOT FULLY PENETRATED.