Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 09/27/2001 |
ELECTRIC - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 08/23/2001 |
ELECTRIC - FINAL |
|
Denied |
IVRS - Inspection 0999*1.) ACCESS TO ELECTRIC SERVICE OBSTRUCTED BY ADDITION. A 30" X 30" UN OBSTRUCTED WORK AREA REQUIRED IN FRONT OFF ELECTRIC SERVICE N.E.C. SECTION 110-26. 2.0 WATER HEATER COMBUSTION AIR REQUIRES 1/4" MESH GRILLS 3.) OUTSIDE HOSE BIBS REQUIRES ANTISIPHON VALUES 4.) CLEAN OUTS REQUIRE PROPER THEADED CAPS. 5.) A/C NOT LEVEL. 6.) A/C DISCONNECT NOT PROPERLY SUPPORTED 7.)NO MAINTENANCE OUTLET FOR A/C WITHIN 25 FT.8.) ABS VENT NOT PROTECTED LATEX. |