Permit: T01CM00515

Parcel: 125051080


Addresses:

625 N NORTON AV

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
04/16/2001 FRAMING Approved IVRS - Inspection 0000*
04/09/2001 FRAMING Denied IVRS - Inspection 0999*/1. PROVIDE GROUND PIG TAILS FOR ALL LIGHT SWITCHES PER 1999 N.E.C. 2. HOLD DOWN ON EAST SIDE OF 60 DOOR MUST BE ATTACHED TO FULL LENGTH DOUBLE STUDS. SEE SIMPSON INSTALLATION MANUAL. 3. SECURE ALL ELECTRIC BOXES IN PERMANENT LOCATIONS. ONE CIRCUIT LAYING LOOSE ON FLOOR. 4. GROUND ALL METAL ELECTRIC BOXES. LOCK NUTS ARE NO LONGER APPROVED GROUNDS.