Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 03/13/2001 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 03/07/2001 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999* STAIR STEPS AT REAR OF BUILDING DO NOT MEET MINIMUM CODE REQUIREMENTS OF 7"RISE / 11" RUN SEE SEC 1003.3.3.3 U.B.C |