Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 05/15/2001 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 05/14/2001 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) PAINT EXTERIOR PVC 2) CONNECT AIR HANDLER 3) REMOVE INSULATION FROM SECONDARY CONDENSATION DRAIN LINE 4) REMOVE COMBUSTIBLE MATERIAL FROM WITHIN 1 INCH OF FURNACE FLUE PIPE VENT |
| 05/11/2001 |
BUILDING - FINAL |
|
Denied |
1) POST TENSION TAG AT WATER LINE 2) NO ACCESS TO ATTIC |
| 05/10/2001 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ IDENTIFY ADDRESS AT PANEL 2) SECURE AC FLEX LINE AT CONDENSOR 3) BLOW BACK INSULATION AT EAVE VENTS 4) SEAL PENETRATION AT AC REFRIGERENT LINE 5) PAINT EXT PVC AT WATER IRRIGATION POST TENSION TAG IT 6) AIR HANDLER NOT CONNECTED 7) SECURE DISHWASHER WASTE LINE TO WITHIN 2 INCHES OF FLOOD RIM |