Inspection Status: Approved
Inspection History: ROOF NAILING
| Date |
Description |
Inspector |
Results |
Comments |
| 03/27/2001 |
ROOF NAILING |
|
Approved |
IVRS - Inspection 0000* |
| 03/21/2001 |
ROOF NAILING |
|
Denied |
IVRS - Inspection 0999*/1. FRONT PORCH RAFTERS MUST BEAR ON LEDGER AT HOUSE SIDE. 2. FRONT PORCH RAFTERS MUST HAVE U24 HANGERS ON SOUTH SIDE. SEE SECTION A OF PLAN. 3. PORCH SILL PLATES NOT ANCHORED. 4. PORCH LEDGER MUST BE CLIPPED WITH A35 CLIPS TO PREVENT SEPARATION. 5. FRONT PORCH MISSING BLOCKING SEE SECTION A. 6. ADDITION MISSING ANCHOR OBLTS. 7. EXTERIOR SHEATHING EDGES MUST LAND ON FRAME MEMBERS. 8. RAFTERS NOT CLIPPED. 9. APPROVED PLANS NOT ON SITE. |
| 03/09/2001 |
ROOF NAILING |
|
Denied |
IVRS - Inspection 0999*/REVISE PLAN FOR ADDITIONAL WORK TO CARPORT AND FRONT PORCH. BEFORE NEXT INSPECTION CAN BE DONE. |