Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 05/02/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 05/01/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0950$ |
| 04/27/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/1) BATHROOM LAV TRAP WEIR ? CANNOT BE ABOVE VENT OPENING 2) STUD MISSING AT CLOSET-MECH ROOM WALL 3) WIRES OBSTRUCT ATTIC ACCESS 4) PEX LEAK AT MECH ROOM 5) EXHAUST FANS MUST EXHAUST OUTSIDE 6) CHECK DRYER "T" CAP FOR GRILL 7) BACK GROUT TUB FLOOR PENETRATIONS |
| 04/26/2001 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/1) PROTECT VENTS AT BOTH BATHROOMS 2) SECURE BRACE FOR DUCT AT BATHROOM 3) VENT BLOCKED AT 3 SIDES 4) FINISH FRAMING AT FURNACE 5) SECURE PEX AT BATHROOM 6) SEAL RACEWAY PANEL 7) FIRE BLOCK A T GUEST BATH |