Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T01CM00364

Parcel: 141111250

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T01CM00364

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
04/12/2001 FRAMING Approved IVRS - Inspection 0000*
04/11/2001 FRAMING Denied IVRS - Inspection 0999*/MID-SPAN GLUE LAM BRACKET NOT NAILED IN GARAGE, STRAP TOP PLATES WHERE GAS LINE PENETRATES ON REAR GARAGE SHEARWALL, SHIM WHERE NEEDED-HEADERS, STAIR LANDING, CHECK WATER LEAK IN LOWER BATH, NEED MIDSPAN X BRACING IN MAIN TRUSSES