Permit: T01CM00357

Parcel: 111041860


Addresses:

3503 E HARDY DR

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
10/10/2001 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000*1.) SOIL WATER TEST IS OK 2.) OVERHEAD WATER DISTRIBUTION IS OK 3.) REVISED & APPROVED DRAWING IS OK 4.) OK TO DRYWALL UPON BLDG INSPECTION APPROVAL.
10/08/2001 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*1.) NO APPROVED DRAWING ON SITE AS REQUESTED 2.) MUST PAY REINSPECTION FEE BEFORE NEXT INSPECTION 3.) DO NOT COVER WALLS.
10/03/2001 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*1.) BLDG LOCKED UNABLE TO ACCESS APPROVED PLAN. 2.) RE-INSPECTED 2:30PM NO APPROVED REVISED PLAN YARDWATER OK PRESSURE TEST OK.OK TO BACKFILL.
09/18/2001 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*1.) SUPPORT 2" X 4" HORIZONTAL BRACE FOR PIPING TO TOP PLATE OF WALL. 2.) ABS TO BE SUPPORTED EVERY 4' MAX 3.) WATER PIPING NOT INSTALLED PER PLAN ISOLATION VALVES. 4.) HOSE BIBS NOT INSTALLED PER PLAN REG. JOSAM 5.) NO WATER TEST ON ABS FILL TO HIGHEST VENT 6.) NO TEST ON COPPER 50# MINIMUN.