Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
Permit Number - T01CM00353
Inspection Description - PLUMBING - FINAL
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/12/2001 | PLUMBING - FINAL | Approved | IVRS - Inspection 0000*FINAL OK S.T.O.I CORRECTION HAVE BEEN MADE AS PER LAST REQUEST. | |
07/11/2001 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*1.) SINK REQUIRES TO HAVE A C.O. | |
05/31/2001 | PLUMBING - FINAL | Partial Approval | IVRS - Inspection 0000*1)PLUMBING FINAL FOR PHOTO LAB AREA IS OK.2)FIXTURES FOR AUTOMOTIVE DEPT OK. | |
05/30/2001 | PLUMBING - FINAL | Denied | IVRS - Inspection 0999*1)WATER HEATER MUST HAVE EXPANSION TANK DUE TO CLOSED SYSTEM.2)WATER HEATER P AND T DRAIN CAN NOT HAVE FLEX LINE.3)ABS FITTINGS ON WASTE AND VENT SYSTEM MUST BE REMOVED AND REPLACED WITH PVC FITTINGS.THE GREEN TRANSISION GLUE IS APPROVED FOR EXTERIOR OF STRUCTURE ONLY.4)BACK FLOW PREVENTER REQUIRES A DRAIN INDIRECT TO FLOOR DRAIN.5)FLOOR DRAIN REQUIRES A FUNNEL FOR INDIRECT WASTE RECEPTOR FOR P AND T AND BACK FLOW PREVENTER DISCHARGE DRAIN.6)REQUIRE TEST AND CERTIFICATION FOR BACK FLOW DEVICE.7)MUST ANCHOR SINK TO CABINET.8)MUST SECURE 3/4 COPPER WATER LINE IN COLUMN. |