Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 05/30/2001 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 05/22/2001 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) REVISIONS: FOR SHEAR WALLS, WORKING THRU CITY FOR CITY STAMP, SAW ORIGINALS, STAMPED BY ENGINEER OF RECORD 2) CHECK A-3 FOR ATTIC/VENT SIZE AND LOCATION 3) NAIL ALL EXT SHEATHING WALLS S/WEST CORNER, REV CALLS FOR 4"-12" WITH 8DS SEE EQUIVALENTCHART LEFT WITH PERMIT CHECK ALL SHEAR NAILING 4) BLOCK DUCT WORK IN FURNACE, ROOM, MOVE WIRE AWAY FROM FLUE BLOCK OFF RETURN PLENIUM FOR INSULATION 5) TIGHTEN ALL AD NUTS 6) TIE BAY WINDOW WALLS TOGETHER, WITH 2 X AND NAILS 7) DOUBLE STUD UNDER GIRDER 8) NEED TRUSS DRAWINGS ON SITE TO CHECK INTERIOR BEARING PTS 9) KITCHEN WALL MISSING FIRE/BLOCKING 10) MOVER CONDENSATES AWAY FROM CAN LIGHTS EAST CLOSET 11) NO LADDER TO ACCESS MECHANICAL AREAS |
| 05/18/2001 |
FRAMING |
|
Denied |
|