Inspection History Details
Permit: T01CM00340
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/08/2001 | ELECTRIC - FINAL | Approved | IVRS - Inspection 0000* CORRECTIONS ARE OK. OK TO CLEAR RECONNECT | |
| 01/25/2001 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0245* NOTES CONDUIT ON ALL WALLS NEED TO BE SUPPORTED PER N.E.C. 348-13. WITHIN 3' EACH BOX AND AT 10' INTERVALS OUTSIDE BACK LIGHT NEEDS COVER FOR LAMP FOR BREAKAGE RESISTANCE. BULB EXPOSED AND HANGING DOWN TO LOW. WIRING FOR HEATER NEED TO BE IN CONDUIT, AND FUSE STAT INSTALLED WITH SWITCH FOR MOTOR. BACKPLATE MISSING. INSTALL BLANK PLATE FOR EXPOSED BOX ON WEST WALL MISSING RECEPTACLE PLATES 500 WATT QUARTZ SECURITY LIGHTING OUTSIDE EAST WALL ARE IN VIOLATION OF CITY LIGHTING ORDINACE, INSTALL SHIELDS |