Permit: T01CM00340


Addresses:

5527 E PIMA ST


Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T01CM00340

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
02/08/2001 ELECTRIC - FINAL Approved IVRS - Inspection 0000* CORRECTIONS ARE OK. OK TO CLEAR RECONNECT
01/25/2001 ELECTRIC - FINAL Denied IVRS - Inspection 0245*
NOTES CONDUIT ON ALL WALLS NEED TO BE SUPPORTED PER N.E.C. 348-13. WITHIN 3' EACH BOX AND AT 10' INTERVALS
OUTSIDE BACK LIGHT NEEDS COVER FOR LAMP FOR BREAKAGE RESISTANCE. BULB EXPOSED AND HANGING DOWN TO LOW.
WIRING FOR HEATER NEED TO BE IN CONDUIT, AND FUSE STAT INSTALLED WITH SWITCH FOR MOTOR. BACKPLATE MISSING.
INSTALL BLANK PLATE FOR EXPOSED BOX ON WEST WALL
MISSING RECEPTACLE PLATES
500 WATT QUARTZ SECURITY LIGHTING OUTSIDE EAST WALL ARE IN VIOLATION OF CITY LIGHTING ORDINACE, INSTALL SHIELDS