Inspection Status: Denied
Inspection History: ROOF NAILING
| Date |
Description |
Inspector |
Results |
Comments |
| 03/08/2002 |
ROOF NAILING |
|
Denied |
IVRS - Inspection 0999*1.) PORCH BEAM NOT PER PLAN 1/A2 REQUIRES 6 X 10 ROUGH WITH SIMPSON HARDWARE SADDLES OR HARDWARE 6 X 8 INSTALLED WITHOUT BEAM. 2.) BEDROOMS REQUIRE 4 X10 GLUE LAM BEAM WITH SIMPSON. 6 X 8 ROUGH SAWN INSTLALED W/0 HARDWARE 3.) FAMILY ROOM JOIST BLOCKING NOT INSTALLED 4.) PROVIDE CITY APPROVED DETAIL FOR ANCHORING LEDGER AT EXISTING SOUTH WALL WHICH ISN OT PER 2 /52 ALSO PERLIN ANCHORS INSTALLED WITH 3/4" WEDGE READY. ROOF SHEATHING IS NAILED PER PLAN & LOAD AND RAFTERS/JOISTS ARE PER PLAN BEAMS ARE NOT. PROCEED AT YOUR OWN RISK. |