Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 03/05/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 03/02/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/1. BIRD BOARDS NAILED. 2. HORIZONTAL STRAPPING ON FRONT ENTRY CONVEY HEADERS. |
| 03/01/2001 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/1. STRAP NON-CABIN TIED TOP PLATES. 2. STRAP CONVEX HEADERS OVER FRONT DOOR. 3. STRAP CUT SOLE PLATES. 4. STRAP WEST MIDDLE WINDOW HEADER. 5. FINISH NAILING OFF ROOF-10 +/- PANELS NOT NAILED. 6. PATIO ROOF NOT DONE. 7. NO BIRD BOARD NAILING. |