Permit: T01CM00271

Parcel: 141147660

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
03/26/2001 FRAMING Approved IVRS - Inspection 0000*
03/23/2001 FRAMING Denied IVRS - Inspection 0999*/1. MOVE REGISTERS OR GET NEW PAPERWORK FOR LOCATION CHANGES IN KITCHEN AND MASTER BED. REMOVE TAR PAPER FROM FLUE STRAP ALL TOP PLATES AT FAMILY ROOM WALLS. 7. SECURE METAL CHASE TO WALL FOR DIRECT VENT FLUE.
03/21/2001 FRAMING Denied IVRS - Inspection 0999*/1. SHIM DUCT FROM TOP OF CANLIGHTS IN KITCHEN. 2. MOVE REGISTERS OR GET NEW PAPERWORK FOR LOCATION CHANGES IN KITCHEN AND MASTER BED. 3. EXTEND SECONDARY CONDENSATE LINE TO EXTERIOR IN 5TH BEDROOM. 4. REMOVE TAR PAPER FROM FLUE. 5. STRAP ALL TOP PLATES AT FAMILY ROOM WALLS. 6. SHIM HEADERS NEXT TO FIREPLACE (WINDOWS). 7. SECURE METAL CHASE TO WALL FOR DIRECT VENT FLUE. 8. CLIP MASTER BEDROOM DOOR KING STUD (SHEARWALL)
03/20/2001 FRAMING Not ready for Inspection IVRS - Inspection 0000*
03/12/2001 FRAMING Not ready for Inspection IVRS - Inspection 0000*