Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T01CM00269

Parcel: 141146080

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
02/28/2001 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
02/23/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/NO CORRECTIONS MADE.
02/21/2001 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/1. TRIANGLE PIECE OF OSB NOT NAILED AT FRONT LEFT GARAGE ROOF. 2. 1 STUD CLIP NOT NAILED AND OTHER CLIPS MISSING. 3. DIAGONAL BRACING NEEDS 2 NAILS AT TOP AND BOTTOM. 4. SHEAR WALL NOT NAILED OFF-LEFT OF FRONT WINDOW AND OVER FRONT DOOR. 5. INSTALL ALTERNATE HOLD DOWN AT FRONT WINDOW.