Inspection History: FRAMING

Date Description Inspector Results Comments
04/25/2001 FRAMING Approved IVRS - Inspection 0000*
04/12/2001 FRAMING Partial Approval SEAL THE CRACK AT THE COMBOSTIBLE HEARTH, NEED APROVAL FOR 8" REQUIREMENT AT FIRE BOX, REMOVED 4" OF BRICK AT FIRE BOX UBC 3102.7.3, NEED A HEARTH EXTENSION, GAS TEST OK, INSTALL ALL NAIL PROTECTION FOR H20 LINES AND ROMEX, UNCOVER SOIL LINES, INSULATE ALL BUT FIRE PLACE
04/06/2001 FRAMING Not ready for Inspection IVRS - Inspection 0000*/KITCHEN H/P BEAM ADD STUD FOR BEARING.
03/28/2001 FRAMING Not ready for Inspection IVRS - Inspection 0000*