Permit: T01CM00227

Parcel: 12709011E

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T01CM00227

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
02/05/2001 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000*
SOIL WATER TEST OK
P.O.C. OF NEW BLDG DRAIN TO EXSISTING BLDG DRAIN OK
OVERHEAD WATER DISTRIBUTION OK
OK TO BACKFILL TRENCH
OK TO DRYWALL UPON BLDG INSPECTORS APPROVAL
ALL CORRECTIONS HAVE BEEN MADE
02/01/2001 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*
HORIZONTAL WASTE LINE EXCEEDS 135 DEGREE AT P.O.C. SEE SECTION:705.5 94 UPC
HORIZONTAL VENT MUST HAVE A HANGER WITHIN 18" OF JOINT, SEE SECTION 314.2 INSTALLATION STANDARDS 94 UPC