Permit: T01CM00202

Parcel: 140420740


Addresses:

7250 S TUCSON BL


Inspection Status: Approved

Inspection History: MECHANICAL - ABOVE CEILING

Permit Number - T01CM00202

Inspection Description - MECHANICAL - ABOVE CEILING

Inspection Status - Approved

Date Description Inspector Results Comments
01/12/2005 MECHANICAL - ABOVE CEILING Approved IVRS - Inspection :*
01/04/2005 MECHANICAL - ABOVE CEILING Partial Approval IVRS - Inspection :* EAST END OF LINK HARD?? OK TO COVER
10/20/2004 MECHANICAL - ABOVE CEILING Partial Approval IVRS - Inspection :*/2ND FLR. WEST TICKETING, SUPPLY AIR ALL INSUL. OK TO COVER SOFFITT. 1ST FLR. WEST BAGGAGE, OK TO COVER
10/04/2004 MECHANICAL - ABOVE CEILING Partial Approval IVRS - Inspection :*/ 1) LINK CORRIDOR-SUSPENDED ROUGH DUCT 2) OK TO BEGIN INSULATION DUCT
06/21/2004 MECHANICAL - ABOVE CEILING Partial Approval 4-A AREA WEST - BAGGAGE LEVEL - SUPPLY DUCTS OFF A/H #101 IN SOFFITS, OK TO INSULATE.
04/15/2004 MECHANICAL - ABOVE CEILING Partial Approval IVRS - Inspection 0000*/ EAST SIDE BAGGAGE AREA - SUSPENDED ROUGH DUCT IN SOFFIT.
03/02/2004 MECHANICAL - ABOVE CEILING Partial Approval IVRS - Inspection 0000*/ 1) EAST BAGGAGE AREA, 2 1/2" STEEL MAIN, HW LOOP TO 2" CU IN SOFFIT. HARD DUCT ALREADY INSPECTED. 60 PSI
02/06/2004 MECHANICAL - ABOVE CEILING Partial Approval IVRS - Inspection 0000*/ 4-B EAST - SOFFITT AREA, SUPPLY DUCT - SUSPENDED.
12/29/2003 MECHANICAL - ABOVE CEILING Partial Approval IVRS - Inspection 0000*/ 4B WEST - DUCT IN SOFFIT - OK TO COVER.
12/11/2003 MECHANICAL - ABOVE CEILING Partial Approval IVRS - Inspection 0000*/ WEST MENS RESTROOM, UNISEX RESTROOM. LOWER LEVEL, PHASE 2. OK TO COVER EXHAUST DUCT.
09/15/2003 MECHANICAL - ABOVE CEILING Partial Approval IVRS - Inspection 0000*/ AREA 2A - 2B - OK TO COVER GRID. LOWER LEVEL. 2B TOP LEVEL - OK TO COVER GRID.
09/10/2003 MECHANICAL - ABOVE CEILING Partial Approval IVRS - Inspection 0000*/1) WEST SIDE, LOWER LEVEL, AREA 2B. OK TO COVER GRID. 2) WEST CENTRAL , 2A. OK TO COVER GRID.
09/08/2003 MECHANICAL - ABOVE CEILING Partial Approval IVRS - Inspection 0000*
06/12/2003 MECHANICAL - ABOVE CEILING Partial Approval IVRS - Inspection 0000*
06/11/2003 MECHANICAL - ABOVE CEILING Partial Approval IVRS - Inspection 0000*
06/03/2003 MECHANICAL - ABOVE CEILING Partial Approval 1) 2 HOUR ENCLOSURE CLEAR COMBUSTIBLES ON REAR EXISTING SIDE OF COMB. DAMPER THAT ? REACHED. AREA 2 BLOWER AREA. AREA 2 A TOP FLOOR AIR HANDLERS-NEED TO PROVIDE ACCESS FOR REPLACING WHEN NECESSARY. PROPER SERVICE ACCESS LIGHTS
05/05/2003 MECHANICAL - ABOVE CEILING Partial Approval IVRS - Inspection 0000*2ND FLR HWS/ TO VAV BOXES, WEST SIDE 9 VAV'S 120 PSI.
12/06/2002 MECHANICAL - ABOVE CEILING Partial Approval IVRS - Inspection 0000*
SUPPLY RETURN CHILLED WATER LINES TO VAV (CONTINENTIAL TICKET COUNTER.) 60 PSI 3/4" LINE.