Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T01CM00202
Inspection Description - FRAMING
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/18/2005 | FRAMING | Approved | 1) PLUMB, ELECT, MECH, NEED TO BE FINALED. 2) FIRE SPRINKLER FINAL 3) ALARM SYSTEM FINAL | |
| 12/30/2004 | FRAMING | Partial Approval | IVRS - Inspection :* P LINK CEILING OK | |
| 12/22/2004 | FRAMING | Partial Approval | IVRS - Inspection :* 1) NEED PANELS AT WEST END CANOPY |
|
| 12/17/2004 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 12/14/2004 | FRAMING | Partial Approval | IVRS - Inspection :*LINK OK | |
| 12/03/2004 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 12/01/2004 | FRAMING | Partial Approval | IVRS - Inspection :*/SOFFITS & ALCOVES IN LINK OK | |
| 11/22/2004 | FRAMING | Partial Approval | IVRS - Inspection :REPORTS OK IN KINK HARD LIDS WEST BAGGAGE OK YOU STILL NEED FIRESTOP @ SEVERAL SPRINKLER PIPE LOCATIONS ALL PROGRESS OK EXTERIOR & INTERIOR YOU NEED TO FINISH FIRESTOP @ SEVERAL SPRINKLER PIPE PENETRATIONS AND AT SOME EXISTING DAMAGED AREAS ALONG SOUTH EXTERIOR WALLS I STILL NEED TO INSPECT INSIDE TUNNELS 1,2,7,8 |
|
| 11/10/2004 | FRAMING | Partial Approval | IVRS - Inspection :*/ 1) OK TO COVER SOFFITS IN LINK 2) NICHES AT LINK OK | |
| 11/08/2004 | FRAMING | Partial Approval | IVRS - Inspection :*/ 1) WEST TICKET COMPLETE 2) DO NOT COVER PASS THRU CEILING UNTIL FIRESTOP INSPECTED |
|
| 11/01/2004 | FRAMING | Partial Approval | IVRS - Inspection :*WEST BAGGAGE & TICKETING ESSENTIALLY COMPLETE | |
| 10/20/2004 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 10/19/2004 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 10/18/2004 | FRAMING | Partial Approval | IVRS - Inspection :ALL PROGRESS OK | |
| 10/14/2004 | FRAMING | Partial Approval | IVRS - Inspection :*/ALL PROGRESS OK. REPAIR MONOKOTE TYEKET? LEVEL WEST END BEFORE COVERING SOFFITS | |
| 10/07/2004 | FRAMING | Partial Approval | IVRS - Inspection :* WEST TICKET WEST WALL & STRUCTURAL STEEL AWNING @ WEST | |
| 10/01/2004 | FRAMING | Partial Approval | IVRS - Inspection :*PARTIAL APPROVAL. ALL PROGRESS WEST T & B OK. | |
| 09/21/2004 | FRAMING | Partial Approval | IVRS - Inspection :*PARTIAL APPROVAL. WEST AREA PROGRESS OK. | |
| 09/15/2004 | FRAMING | Partial Approval | IVRS - Inspection :*/ 1) ALL C.F.S. PROGRESS IN WEST AREA OK 2) SOUTH WALLS EAST VAULT OK 3) SOUTH EXTERIOR SHEATHING AT LINK OK | |
| 09/10/2004 | FRAMING | Partial Approval | PROGRESS WEST BAGGAGE OK CFS FRAMING, ?? AND SOFFITS IN LINK OK | |
| 09/07/2004 | FRAMING | Partial Approval | IVRS - Inspection :*/ 01035-1) ALL PROGRESS WEST BAGGAGE AREA OK (SOFHTS?, LIDS, WALLS ETC.) 2)PROGRESS WEST TICKET LEVEL ON SEFHTS? & PARNPETS? OK 3)HARD LID @ EAST FLYING ARCH OK (AND PARAFET? RETURN) 4)HARD LID @ HIGH LINK OK (EAST OF BARRELARCH) 5)PAMPETS @ LINK AREA OK (REPAIR WHERE DAMAGED BY ROOFERS) |
|
| 08/31/2004 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 08/30/2004 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 08/26/2004 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 08/24/2004 | FRAMING | Partial Approval | IVRS - Inspection :*/PARTIAL SOUTH WALL & PARAPETS? LINK OK 1045-PARTIAL-PROGRESSED-TECKET LEVEL E 01015-UPPER PEDESTRIAN RAMP @ LINK OK 01030-FLAT ROOF OVER LINK OK |
|
| 08/19/2004 | FRAMING | Partial Approval | IVRS - Inspection :* BARREL ARCH AREA B | |
| 08/17/2004 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 08/16/2004 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 08/12/2004 | FRAMING | Partial Approval | IVRS - Inspection :*/1)AREA B BAGGAGE PROGRESS OK WALLS, CIELINGS, COLUMNS, SUFFITS, ETC. 2)REPAIR MONOKOTE ON COLUMNS & BEAMS AND RECALL INSPECTION BEFORE COVERING. 3)C.F.S. LIDS, SOFTLIS ETS. OK AREA E TICKET LEVEL DO NOT COVER WHERE MONOKOTE REQUIRES REPAIR UNTIL REPAIRS HAVE BEEN INSPECTED. 4) CIELING EASTEND AREA E BAGGAGE SITLL NOT READY 5) MONOKOTE DAMAGE AREA E BAGGAGE STILL NOT REPAIRED PLEASE MAKE MONOKOTE REPAIRE AT BAGGAGE LEVEL BEFORE CONTINUING. |
|
| 08/10/2004 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 08/05/2004 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 07/27/2004 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 07/21/2004 | FRAMING | Partial Approval | IVRS - Inspection :ALL C.F.S. PROGRESS AREA E BAGGAGE LEVEL OK OK TO COVER WALLS, SOFFITS, HARD LIDS AS COMPLETED |
|
| 07/13/2004 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 06/29/2004 | FRAMING | Partial Approval | IVRS - Inspection :*/ 1) FRAME PROGRESS AREA B BAGGAGE OK FOR CEILINGS, SOFFITS AND WALLS 2) SOUTH SIDE OF WEST BARREL ARCH OK AT LOW ROOF | |
| 06/24/2004 | FRAMING | Partial Approval | IVRS - Inspection :*/ 1) EAST TICKET KNIFE WALL | |
| 06/21/2004 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 06/02/2004 | FRAMING | Partial Approval | IVRS - Inspection :* SOFFIT FRAMING E ELEV SHAFT ROOF- HEAVY STRUCTURAL VARIOUS AREAS. PROGRESS WITH C.F.S. & SHEET ROCK IS OK | |
| 05/25/2004 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 05/21/2004 | FRAMING | Partial Approval | IVRS - Inspection :* | |
| 05/17/2004 | FRAMING | Partial Approval | IVRS - Inspection :*/ 1) TO PROGRESS AREA E BAGGAGE LEVEL OK | |
| 05/05/2004 | FRAMING | Partial Approval | IVRS - Inspection :*/ 1) PROGRESS ON C.F.S. PARAPETS OK 2) PROGRESS ON STRUCTUAL STEEL AREA E OK | |
| 04/21/2004 | FRAMING | Partial Approval | IVRS - Inspection 0000* 1) PROGRESS ON STRUCT STEEL AREA E OK. 2) PROGRESS LUGGAGE LEVEL CFS AREA E OK | |
| 04/14/2004 | FRAMING | Partial Approval | IVRS - Inspection 0000* EAST BAGGAGE AREA OFFICE OK. | |
| 03/16/2004 | FRAMING | Partial Approval | IVRS - Inspection 0000* CEILING FRAME TICKET LEVEL BY WEST ESCALATOR | |
| 03/10/2004 | FRAMING | Partial Approval | IVRS - Inspection 0000* SOFFIT TICKET LEVEL BY FRONTIER AIRLINES OK | |
| 03/02/2004 | FRAMING | Partial Approval | IVRS - Inspection 0000* REAR BAGGAGE AREA EAST END | |
| 02/26/2004 | FRAMING | Partial Approval | IVRS - Inspection 0000* 1) COLD FORM STEEL FRAMING OK INSIDE BAGGAGE LEVELS. 2) DO NOT COVER!!! UNTIL I SEE MONOKOTE REPAIRS. | |
| 12/11/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000* MEN'S & FAMILY RESTROOMS LIDS OK | |
| 12/10/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000* LIGHT GAUGE STEEL FRAMING OK FOR MENS AND FAMILY RESTROOM AREA BY TUNNEL 2 OK. | |
| 09/30/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) 2 HR CENTRAL BAGGED SIDE OK | |
| 09/26/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000*/1) FIRE STOP 2 HOUR BAGGAGE AND INSIDE TUNNEL. 2) SUPPLY TEST RESULTS FOR FIRE BARRIER ETC. 3) ADA SIGNAGE READILY VISIBLE. | |
| 07/21/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) CONTINUED PROGRESS ON LIGHT GAUGE FRAMING ON BAGGAGE AND TICKETING LEVELS. GENERALLY OK, NO DEFICIENCIES NOTED | |
| 07/15/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) SUSPENDED CEILING BAGGAGE AREA COMPLETE | |
| 07/11/2003 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000* | |
| 07/02/2003 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000* | |
| 06/26/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) PROGRESS "FRONT OF STONE" BAGGAGE LEVEL | |
| 06/25/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) SOUTH WALL LINK AREA 2) SOFFIT FRAMING BAGGAGE AREA | |
| 06/18/2003 | FRAMING | Partial Approval | 1) SUB ROOF FRAMING CENTRAL BAGGAGE-OK | |
| 06/10/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000*/ 1) PROGRESS IN BAGGAGE LEVEL FRAMING A) DO NOT COVER HARD LID IN CORRIDOR UNTIL FIRE STOP INSPECTION HAS BEEN COMPLETED BY CITY OF TUCSON (MYSELF) B) PRVOIDE ARCHITECT STAMPED RFI FOR SUSPENDING HARD LID IN CORRIDOR. (WIRE SUSPENSION AT LEADING EDGE DUE TO CONDUIT BLOCKING STUDS FROM BEING ATTACHED A CEILING 2) WINDOW WALL AT TICKET LEVEL OK 3) SOFFITS COMPLETE AROUND EAST BARREL ARCH 4) CEILING IN WEDGE (DELTA) OK 5) CEILING IN WEST BARREL ARCH OK 6) HIGH SOUTH SOFFIT AND NORTH SOFFIT AROUND WEST BARREL ARCH OK | |
| 05/12/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000*DECK WELDS & STRUCTURAL STEEL @ LINE AREA APPEAR OK I STILL NEED SPEC INSP ON STRUCTURAL WELDS. | |
| 05/06/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000*INSPECTED VARIOUS AREAS TICKET AND BAGGAGE LEVEL NON STRUCTURAL FRAMING 2.) HIGH CIELING INSIDE TERMINAL OK |
|
| 04/25/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000*PARTIAL 1.) MONOKOTE ON STRUCTURAL STEEL IN WEST BARREL ARCH OK I STILL NEED TO SEE SPECIAL INSP. REPORT FROM TERRACON. |
|
| 04/23/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000*PRELIMARY INSP DECK & STRUCT. FRAME @ CANOPY. | |
| 04/22/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000*C1 TO D/110-111. CEILING BAGGAGE LEVEL 22-24/B-C | |
| 04/11/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000*FIRE @ HIGH BARREL ARCH AREA D. 2.) MONOKOTE REPAIR COMPLETE @ BAGGAGE LEVEL 21-25/B1-C1. 3.) RFI FOR W16 BEAM TO EMBED REPAIRS REVIEWED (RFI 244-249) REPAIR OK |
|
| 04/10/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000* | |
| 03/31/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000*1.) FRAMING EAST AREA BAGGAGE LEVEL RESTROOM OK 2.) DO NOT COVER UNTIL. SPRAY ON FIRE SAFING HAS BEEN REPAIRED AND I HAVE INSPECTED IT. |
|
| 03/26/2003 | FRAMING | Partial Approval | IVRS - Inspection 0000*MET WITH JERRY D. NUNZIO AWS CERTIFIED SPECIAL INSPECTOR FOR TERRACON. WE WENT OVER HIS INSPECTION FOR AREA D, 16-22/Y-2. MEETING WAS SET BECAUSE SPECIAL INSP. REPORTS IN SUNDTS OFFICE FROM TERRACON DO NOT GIVE CORRECT LOCATIONS OF MR DE NUNZIOS' INSPECTIONS 2.) PERM OUR MEETING WELDING HAS BEEN ACCEPTED IN ABOVE AREA. NO BOLTING INSPECTIONS HAVE BEEN PERFORMED. |
|
| 03/17/2003 | FRAMING | Partial Approval | 1.) HEAVY STEEL AREA C NEARLY COMPLETE. 2.) HIGH DELTA @ Y-2/7-11 IN PROGRESS. 3.) I NEED TO SEE RFI FOR STEEL FABRICATED TOO SHORT. |