Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING PRE-SLAB
Permit Number - T01CM00202
Inspection Description - BUILDING PRE-SLAB
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/22/2004 | BUILDING PRE-SLAB | Approved | IVRS - Inspection :* | |
| 12/17/2004 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* | |
| 11/01/2004 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :*/EAST ROADWAYS & SIDE WALKS OK | |
| 10/01/2004 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :*CAUTION-THE CROSS SLOPE OF AN ACCESSIBLE ROUTE MAY NOT EXCEED 2%. CHECK SET WEST BAG. | |
| 08/30/2004 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* | |
| 08/26/2004 | BUILDING PRE-SLAB | Not ready for Inspection | IVRS - Inspection :* | |
| 08/24/2004 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* | |
| 08/19/2004 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* LOWER RAMP SLAB @ LINK | |
| 08/16/2004 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* | |
| 08/13/2004 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* | |
| 08/12/2004 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :*/ 1) TOPPING SLAB WEST TERMINAL AREA OK TO PLACE | |
| 08/05/2004 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* | |
| 07/27/2004 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* | |
| 07/14/2004 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* TOPPING SLAB AREA E | |
| 07/13/2004 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :* | |
| 06/16/2004 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :*/ 1) OK TO PLACE CONCRETE AT BASES OF 6 FLYING ARCHES-EAST END | |
| 05/27/2004 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection :*/ 1) ? AREA E-F CONTINUATION | |
| 04/12/2004 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000* 1) CENTER STIRRUP BEAMS 44, 45 LINE X MISSING. 2) PROVIDE PROPER CLEARANCES AS NOTED @ WALK THRU. 3) OK TO PLACE CONCRETE WHEN SPEC INSP CONFIRMS CORRECTIONS. | |
| 04/09/2004 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000* BEAMS & JOIST STEEL OK. SOME CLEARANCE ISSUES. MAT STEEL CLEARANCES ISSUTES. FINISH FORM WORK. | |
| 03/18/2004 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000* SOG BY TUNNEL 1 OK | |
| 03/05/2004 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000* 1) DECK AREA E A) FINISH CHAIRING & TIEING STEEL ALONG SOUTH LINE FOR PROPER CLEARANCE. B) ALL JOISTS NEED TO BE PROPERLY EXTENDED INTO BEAM ON NORTH LINE TIE & SPACED. C) OK TO POUR WHEN SPEC INSP CONFIRMS FINAL PLACEMENT | |
| 03/04/2004 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000* 1) 38 BARS BOTTOM OF JOISTS ARE TOO SHORT IN SEVERAL LOCATIONS. 2) MISSING 1 #5 T & B @ SLAB EDGE WEST END(BEING ADDED NOW) 3) ADD EDGE PROTECTION @ ELEV PENETRATION PER DETAIL. 4) CLEARANCES. 5) RFI FOR FIX ON #11 BEAM BARS LAPPED TOO SHORT , CALLS FOR #8 BARS BETWEEN #11 NOT BUNDLED WITH. | |
| 03/03/2004 | BUILDING PRE-SLAB | Not ready for Inspection | IVRS - Inspection 0000* | |
| 02/24/2004 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000* SOG TO LINE X | |
| 02/23/2004 | BUILDING PRE-SLAB | Not ready for Inspection | IVRS - Inspection 0000* DECK EAST AREA NOT READY | |
| 01/29/2004 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000* DECK OVER TUNNELS 7, 8 OK | |
| 01/22/2004 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000* PARTIAL SOG AREA E & F a) MOVE #4 HAUNCH OF SLAB DOWELS @TUNNELS & ELEVATOR PIT. b) COMPLETE 36'' X 10" DOWELS @ WINDOW WALL OK TO PLACE CONCRETE WHEN SPEC INSP CONFIRMS ABOVE |
|
| 01/21/2004 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000* PRELIMINARY FOR SOG EAST SIDE OK | |
| 01/08/2004 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000* | |
| 01/07/2004 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000* | |
| 11/12/2003 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000* TUNNEL 7,8 CAP ON AIRPLANE SIDE | |
| 07/21/2003 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000*/ 1) SLAB ON SLAB AT TICKET LEVEL FROM DELTA EAST | |
| 07/08/2003 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000* TICKET LEVEL SLAB OVER SLAB FROM DELTA TO WEST END (LINE1-16) | |
| 06/09/2003 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000*/ 1) SIDE WALK IN " LINK " AREA | |
| 04/23/2003 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000* | |
| 03/05/2003 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000*CLOSURE STRIPS TICKET & ROOF LEVEL LINE A/1-22. | |
| 01/31/2003 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000* | |
| 01/27/2003 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000*1.) SLAB @ TICKET LEVEL X - 2/6-17. 2.) CLEAN UP OF BOTTOM OF FORMS AND MINOR ADJUSTMENTS FOR SIDE AND BOTTOM CLEARANCES ARE NECESSARY. 3.) COMPLETION OF SLAB @Y-Y.S./16-17 NECESSARY. 4.) OK TO POUR AFTER HMW INSPECTOR RICK NOWAK. INSPECTS FOR FINAL COMPLIANCE. |
|
| 01/24/2003 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000*PRESLAB PARTIAL 1.) REINFORCEMENT RINGS ON BEGINS @ CANOPY POST BASES HAVE BEEN SPREAD OFF 12" OC LAYOUT. 2.) RANDOM OCCURANCES OF MISSING OR IMPROPERLY SPACED TOP BARS. 3.) STACKING OF TOP BARS IN BEAMS CORRECTED. |
|
| 01/21/2003 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000*/ 1) CORRECTIONS NOTED BY HMW FROM 1-8 THRU 1-13 HAVE BEEN MADE 2) ENGINEER OK'D 24" VS 36" PAST CENTERLINE FOR BOTTOM BAR REINFORCING, REF B24, B25 AT Y 7-16 3) BASE PLATES FOR CANOPY BUILT UP BOX BEAM MISSING PLATE WASHERS AND DOUBLE NUTS PER 359.9/POUND (X 3/18,20,22). INSTALLATION TO BE CONFINED BY HMW INSPECTOR BEFORE POUR. 4) CLEAN UP AT BOTTOM OF FORMS, ESPECIALLY AROUND COLUMNS IS NECESSARY | |
| 12/17/2002 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000*A-X/1-11.5 2.) TICKET LEVEL A-B/1-7 OK TO POUR. CONFIRMATION OF WELD INSPECTION PER VERBAL WITH. |
|
| 12/13/2002 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000* | |
| 12/11/2002 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000* | |
| 12/06/2002 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000*SLAB CLOSURE @ A21.5 PER RFI 132. | |
| 12/04/2002 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000*SLAB ON GRADE A-2/15-16 | |
| 12/03/2002 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000* | |
| 11/26/2002 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000* | |
| 11/20/2002 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000* | |
| 11/07/2002 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000* | |
| 11/01/2002 | BUILDING PRE-SLAB | Denied | IVRS - Inspection 0999* | |
| 10/25/2002 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000*TUNNEL 3 LOWER SLAB PER REVISED. | |
| 10/23/2002 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000*LOWER SLAB TUNNELY TO CU ON LINE A. PLEASE COMPLETE TRANSITION AREA @ CHANGE IN THICKNESS LINE A. | |
| 10/14/2002 | BUILDING PRE-SLAB | Not ready for Inspection | IVRS - Inspection 0000*RFI 32 BETWEEN TUNNEL 5 & 6 5" SLAB ON GRADE | |
| 09/11/2002 | BUILDING PRE-SLAB | Partial Approval | IVRS - Inspection 0000*AROUND PITS 5 & 6 BAGGAGE OK TO POUR. |