Inspection Status: Approved
Inspection History: STEM WALL/RETAINING WALL
Permit Number - T01CM00202
Inspection Description - STEM WALL/RETAINING WALL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/16/2004 | STEM WALL/RETAINING WALL | Approved | IVRS - Inspection :* | |
| 10/14/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :*/COLUMN BASES WEST END OK | |
| 08/24/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* | |
| 07/29/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* | |
| 07/27/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* | |
| 07/07/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* | |
| 06/04/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* PROGRESS ON WALL @X.5 | |
| 06/01/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* RETAIN WALL CONT. IN LINK AREA OK | |
| 05/27/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* | |
| 05/11/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :* P LINE Y2 100' FROM EAST END | |
| 05/10/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection : See detailed listing on site.| 999*/ 1) RETAIN WALL PLUS 60' LINE Y.2 AND PLUS 60' LINE Y.1 |
|
| 05/04/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection :*/ 1) 60' LINE Y.2 RETAIN AT LINK | |
| 04/21/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000* DECK WELDS AREA E BARREL ARCH INSPECTED BY TERRACON ONLY. C.O.T. DOES NOT SUPPLY SAFETY HARNESS FOR THIS INSP | |
| 04/19/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000* AREA B COLS 6 FORMED COLS OK TO POUR 4 OF 6 UNFORMED STEEL OK, I NEED TO SEE WITH 1/2 FORM 2 NOT READY | |
| 04/16/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000* 8 COLUMNS AREA B A) SPLICE #11 TO REACH TOP WHERE SHORT OR CUT OTHERS TO SHORTEN COL. | |
| 04/15/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000* BOTTOM 12' OF COLUMNS AREA B | |
| 03/17/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000* COL AREA E OK | |
| 03/16/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000* COLS REQUIRED TO CONFORM TO DETAILS ON 359.6. ie RING TIES 3" OR UNDER, BETWEEN AND ON TOP OF EMBEDS. | |
| 03/15/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000* COLUMNS AREA E N/R. REF 2/359.6 FOR TIE SPACING @ EMBEDS. REF: 1A/355.2 FOR OTHER SPACING OF TIES. | |
| 03/11/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000* 6 each cols ticket level | |
| 03/09/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000* TUNNEL WALL @ BAGGAGE 1 OK. 2) REAR OF BAGGAGE PROGESS. | |
| 02/24/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000* E WALL TUNNEL 1 | |
| 02/23/2004 | STEM WALL/RETAINING WALL | Not ready for Inspection | IVRS - Inspection 0000* WALLS TUNNEL 1 NOT READY | |
| 02/09/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000* 1) REMAINDER OF TUNNEL 2 OK. 2) STEEL TUNNEL 1 OK. I NEED TO SEE IT AGAIN WHEN FORMS IN PLACE. 3) PLACE SHAIRS ON RETAINING WALL @ WEST END. | |
| 01/29/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000* ALL COLS BAGGAGE LEVEL AREA B NOW DONE. | |
| 01/26/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000* TUNNEL 2 G.I.P. WALL a)CENTER STEEL IN 8" WALL. b) INSTALL PILASTERS FOR GRADE BEAM. | |
| 01/21/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000* 7 EACH 4' COLS WEST SIDE OK TO CLOSE WHRN SPEC INSP CONFIRMS SPACERS. | |
| 01/16/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000* 1) RAMP WALL LINE A/30-33.1 OK PER RFI 499. 2) REMAINING COLS BAGGAGE LEVEL AREA E | |
| 01/13/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000* | |
| 01/12/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000*/ 1) TUNNEL WALLS 7 1/4 8 2) COLS LINE 33.1 3) RAMP WALL GRID LINE Z1 | |
| 01/09/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000* CAGES OK FOR COLS. 2) CLMS LINE X/104-108 OK TO CLOSE CC3 CLMS LINE 101 OK TO CLOSE | |
| 01/07/2004 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000* | |
| 12/31/2003 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000* 1) C13 COLS LINE 23 OK, CC2 COLS LINE 27, CC2/30, 31/Z1. 2)4' DIAMETER COLS LINE 41 BEING POURED WITHOUT COT INSPECTION. (FAILURE TO GET COT APPROVAL COULD RESULT IN COSTLY DELAYS IN THE FUTURE.) | |
| 12/26/2003 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000* | |
| 12/23/2003 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000* | |
| 12/18/2003 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000* 1) 3 EACH CCI COLS LINE X. 2) 4 EACH CC3 COLS LINE XZ | |
| 11/20/2003 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000* 2ND LEG OF TUNNEL 2 WALLS OK | |
| 11/12/2003 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000* TUNNEL 2 INSIDE BAGGAGE AREA a) ADD #4 HORIZ @ EMBED AS INDICATED OK TO POUR | |
| 10/30/2003 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000* | |
| 08/14/2003 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000* | |
| 05/23/2003 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000* | |
| 04/21/2003 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000*CONCRETE WALL EXTENSION @ 35/A.5 | |
| 03/13/2003 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000*low window lines x & w ok to pour after spec. insp. 2.) horizontal bars near columns req. 1" between 3.) #4 bars to be 3/4" from form 4.) remove wood spaces in form @ west end. |
|
| 02/19/2003 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000*/ 1) PARTIAL-WINDOW WALL AND INTERSECT Y/11.5 | |
| 02/06/2003 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000*1.) REINFORCING STEEL FOR TICKET LEVEL COLUMNS @ X 1, 21 2.) PROVIDE RFI FOR ANY NECESSARY REPAIR OF HONEY COMBING @ COLUMN Z 16. |
|
| 02/05/2003 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000*/ 1) REINFORCEMENT FOR COLUMNS AT TICKET LEVEL 3Y, 3Z, 5Y, 5Z, 7Y, 7Z, 16Y, 16Z 2) SHEARWALL 2-3 LINE A, SHEARWALL 6-7 LINE A 3) ANCHOR BOLTS AND REINFORCEMENT NUTS AT TOP OF COLUMNS STILL NEED TO BE PLACED OBSERVATION TO BE DONE BY HMW SPECIAL INSPECTOR | |
| 01/31/2003 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000*COLUMNS @ Y AND Z 18,20,22 COLUMNS REINFORCEMENT APPEAR IN COMPLIANCE. WORKERS ARE CURRENTLY PLACING FORMS FOR A NIGHT POUR ON 1-31-02. OK TO POUR PROVIDED. 1.) HMW SPECIAL INSPECTOR CONFIRMS PROPER COVER OF STEEL AFTER FORMS ARE COMPLETED. 2.) HMW INSPECTOR CONFIRMS PLACEMENT OF ANCHOR FOR HIGH ROOF @ TOP OF COLUMNS. |
|
| 12/27/2002 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000*SHEAR WALL LINE A/6-7 1.) REINFORCEMENT IN COMPLIANCE EXCEPT #5 EPOXY DOWELS PER 5/355.7 WERE NOT IN PLACE. DESERVED 2 DOWELS PLACE AT EAST END BUT WORK WAS MOVING TOO SLOWLY TO OBSERVE FURTER PLACEMENT. SPECIAL INSP. REQUIRED. 2.) DEBRIS TO BE BLOWN FROM BOTTOM OF FORMS. OK TO POUR AFTER FINAL CLEARANCES OBSERVED BY HMW INSPECTOR. | |
| 12/10/2002 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000* | |
| 12/05/2002 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000*TICKET LEVEL SHEAR WALL LINE A GRID 20-21. | |
| 12/04/2002 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000*SLAB EDGE @ SHEAR WALL TICKET LEVEL LINE A 15.5-16 PER RFI 145. | |
| 12/03/2002 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000*PART SLAB EDGE AT SHEARWALL TICKET LEVEL A/20-21-5 PER RFI 145 | |
| 11/26/2002 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000* | |
| 11/22/2002 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000*PARTIAL 1.) COLUMNS TO BOTTOM OF BEAM @ TICKET LEVEL @ X 3,X5,X 11.5 Y1,Y3,Y5,Y7,Y16,720,Z1,Z3,Z5,Z7,Z16 OK TO POUR. 2.) SHEAR WALL LINE A/6-7 OK TO POUR. 3.) DISCUSSED HOOK PLACEMENT @ SE CORNER OF EAST COL. PER DETAIL 6/355.9 WITH ENGINEER REPRESENTATIVE #4 HOOD ARE FOR CONTROL OF CRACKING @ EDGE AND THUS ARE NOT REQUIRED TO HOOD INSIDE VERTS OF SHEAR WALL. |
|
| 11/21/2002 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000* | |
| 11/15/2002 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000* PARTIAL SHEAR WALL GRID A(20-21) TO BOTTOM OF TIKET LEVEL. AWAITING RFI FOR REPAIR OF CUT SLAB @ TIKET LEVEL. |
|
| 11/05/2002 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000*PARTIAL GRADE BEAM TUNNEL 3 @ 3 B. NOTE EPOXY DOWELS TO EXISTING COLUMN DELETED PER RFI 102. | |
| 11/01/2002 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000* | |
| 10/18/2002 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000*1.) TUNNEL WALLS FOR #5 AND #6. 2.) DETAIL 10/55.12 CALLS FOR 3' X 3' 90 SLAB DOWELS. CONTRACTOR HAS INSTALLED 2' X 3' DOWELS. THIS WAS VERBALLY OK'D BY ENGINEER REPRESENTATIVE. | |
| 10/08/2002 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000*A.1/20.5 PER 5 OR 355.13 | |
| 09/25/2002 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000*1.) PROVIDE RFI FROM HMW CONCERNING ALTERED DESIGN OF CAPS. @ 3' DIAMETER COLUMNS I.E. 90 HOOK DESIGN CHANGE. | |
| 09/24/2002 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000*CAISSON CAPS Y,1,3,5,7,16,18,20 OK TO POUR. | |
| 09/20/2002 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000*CAISSON CAPS @ Y22,Z22,Z18,Z11.5,Z5,Z1 | |
| 09/16/2002 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000*1. X 20 REBAR. 1.) REVIEWED FOR CAISSONS. 2.) TERRACON BRAIN REED WATCHING PLACEMENT OF CONCRETE AND CHECKING DEPTHS FOR CAISSONS. |
|
| 08/27/2002 | STEM WALL/RETAINING WALL | Partial Approval | IVRS - Inspection 0000*RFI-010 & DETAIL 7355.12. PLEASE MAINTAIN CLEARANCES ON SIDES AND ASK MR. NOWAK ABOUT THE 6" CLEAR TOP HORIZONTAL TO UNDERSLAB. |