Permit: T01CM00154

Parcel: 14020013E


Addresses:

5112 S PARK AV

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Date Description Inspector Results Comments
06/30/2004 ELECTRIC - FINAL Approved IVRS - Inspection :*
06/15/2004 ELECTRIC - FINAL Denied IVRS - Inspection :
See detailed listing on site.| 999*/ 1) BATHROOM GFCI NOT PROPERLY WIRED, HOT NEUTRAL REVERSED 2) SUB PANEL IN CLOSET MUST HAVE AN ISOLATED NETURAL BAR AND GROUNDED BOC COPPER AND GREEN WIRES TO GROUND BAR
02/02/2004 ELECTRIC - FINAL Denied IVRS - Inspection 0999*/ 1) TWO NEW CIRCUITS TO ADDITION MUST HAVE A GROUND CONDUCTOR TO SERVICE PANEL 2) SUB PANEL MUST HAVE AN ISOLATED NEUTRAL BAR 3) SUB PANEL MUST BE GROUNDED 4) BATHROOM ELECTRIC OUTLET MUST BE GFCI PROTECTED 5) PLUMBING NOT COMPLETE 6) SMOKE DETECTOR MISSING IN HALL 7) HALL TO NARROW MUST BE 36" WIDE MINIMUM 8) LABEL ALL CIRCUITS IN ALL ELECTRIC PANELS