Inspection History Details
Inspection Status: Approved
Inspection History: ELECTRIC - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/30/2004 | ELECTRIC - FINAL | Approved | IVRS - Inspection :* | |
| 06/15/2004 | ELECTRIC - FINAL | Denied | IVRS - Inspection : See detailed listing on site.| 999*/ 1) BATHROOM GFCI NOT PROPERLY WIRED, HOT NEUTRAL REVERSED 2) SUB PANEL IN CLOSET MUST HAVE AN ISOLATED NETURAL BAR AND GROUNDED BOC COPPER AND GREEN WIRES TO GROUND BAR |
|
| 02/02/2004 | ELECTRIC - FINAL | Denied | IVRS - Inspection 0999*/ 1) TWO NEW CIRCUITS TO ADDITION MUST HAVE A GROUND CONDUCTOR TO SERVICE PANEL 2) SUB PANEL MUST HAVE AN ISOLATED NEUTRAL BAR 3) SUB PANEL MUST BE GROUNDED 4) BATHROOM ELECTRIC OUTLET MUST BE GFCI PROTECTED 5) PLUMBING NOT COMPLETE 6) SMOKE DETECTOR MISSING IN HALL 7) HALL TO NARROW MUST BE 36" WIDE MINIMUM 8) LABEL ALL CIRCUITS IN ALL ELECTRIC PANELS |