Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T01CM00066

Parcel: 125151110


Addresses:

55 E CALLE BELLEZA


Inspection Status: Approved

Inspection History: BUILDING - FINAL

Permit Number - T01CM00066

Inspection Description - BUILDING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
10/31/2001 BUILDING - FINAL Approved IVRS - Inspection 0000*
10/25/2001 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) EXTERIOR PRESSURE RELIEF VALVE REQUIRED ON WATER HEATER 2) LAUNDRY GFCI HOT WHEN TRIPPED ALSO BATH 3) CLOTHES CLOSETS LIGHTS MUST HAVE COVER OVER BULBS 4) FANS MUST HAVE 7' CLEARANCE TO BLADE 5) FIRE PROOF CAULK FIRE PLACE GAS LINE PENETRATION 6) JACCUZI PUMP REQUIRES 12 X 12 ACCESS AND PUMP MUST BE BONDED TO COPPER PLUBMING WITH #8 BOND