Permit: T01CM00066

Parcel: 125151110


Addresses:

55 E CALLE BELLEZA

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
10/31/2001 BUILDING - FINAL Approved IVRS - Inspection 0000*
10/25/2001 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) EXTERIOR PRESSURE RELIEF VALVE REQUIRED ON WATER HEATER 2) LAUNDRY GFCI HOT WHEN TRIPPED ALSO BATH 3) CLOTHES CLOSETS LIGHTS MUST HAVE COVER OVER BULBS 4) FANS MUST HAVE 7' CLEARANCE TO BLADE 5) FIRE PROOF CAULK FIRE PLACE GAS LINE PENETRATION 6) JACCUZI PUMP REQUIRES 12 X 12 ACCESS AND PUMP MUST BE BONDED TO COPPER PLUBMING WITH #8 BOND