Inspection History: POOL/SPA ELECTRIC
Permit Number - T01BU02823
Inspection Description - POOL/SPA ELECTRIC
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/30/2002 | POOL/SPA ELECTRIC | Approved | IVRS - Inspection 0000* | |
| 04/26/2002 | POOL/SPA ELECTRIC | Denied | IVRS - Inspection 0999*1.) WE HAVE MULIPOLE TERMANATION UNDER SCREW NOT LISTED FOR APPLICATED IN SWIMING POOL JUNCITON BOX 110-14. 2.) GFI RECEPTICAL IS NOT ACCESABLE. 3.) PLEASE VERIFY BONDING FOR CANOPY STRUCTURES & FENCE 680-24. 4.) SHEET METAL SCREWS CAN NOT BE USED FOR GROUNDING 250-8. 5.) PLEASE TIGHTEN ALL LOOSE FITTINGS 6.) PLEASE EXPOSE ALL BOND CONNECTION IN EQUIPMENT ENCLOSURE AREA FOR INSPECITON. 7.) ALL STRANDS OF CONDUCTORS ARE TO BE UNDER TERMANATION LUGS. 8.) FINISH ALL TERMNATIONS 9.) THE CORRECT SIZED STRUT CLAMPS ARE NEEDED. 10.) PLEASE LABEL PANEL ON OUTSIDE COVER. | |
| 04/05/2002 | POOL/SPA ELECTRIC | Partial Approval | IVRS - Inspection 0000*MEET WITH SUPER INTENDANT, GATE PEOPLE, & TO DISCUSS 50V AMP LESS METHODS. | |
| 04/04/2002 | POOL/SPA ELECTRIC | Not ready for Inspection | IVRS - Inspection 0000* | |
| 04/03/2002 | POOL/SPA ELECTRIC | Partial Approval | IVRS - Inspection 0000*OK OF UNDERSIDE WALK FOR LIGHT POLES OK OF FOR PLANTERS. WE HAVE PVC RUNS THAT WERE BURIED WITHOUT INSEPCTION WHAT ARE THEY FOR. | |
| 04/01/2002 | POOL/SPA ELECTRIC | Partial Approval | IVRS - Inspection 0000*OK 4-1" PVC BUILDING OUT TO CARD READERS. | |
| 03/15/2002 | POOL/SPA ELECTRIC | Partial Approval | IVRS - Inspection 0000*OK 3/4" PVC FOR BOLLARDS | |
| 02/15/2002 | POOL/SPA ELECTRIC | Partial Approval | IVRS - Inspection 0000*OK 8-BULLARDS NORTHEAST & EAST SIDES 3/4" PVC. OK 3 3/4 PVC FROM PANEL TO AWNING OK 3-BOLLARDS SOUTH SIDE 3/4" PVC OK BRASS AND HANDRAIL BONDS. | |
| 02/14/2002 | POOL/SPA ELECTRIC | Partial Approval | IVRS - Inspection 0000*OK 3/4" PVC TO (3) BOLLARDS NORTWEST SIDE. | |
| 01/07/2002 | POOL/SPA ELECTRIC | Partial Approval | IVRS - Inspection 0000*OK 2-1 1/2 PVC SLEEVES FOR LIGHT FIBER. | |
| 01/06/2002 | POOL/SPA ELECTRIC | Partial Approval | IVRS - Inspection 0000* | |
| 01/03/2002 | POOL/SPA ELECTRIC | Partial Approval | IVRS - Inspection 0000*1.) PVC RACE WAY TO BE ELECTRIC LISTED ENTIRE LENGTH OF RUN. |