Permit: T01BU02685

Parcel: 137115280

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
11/08/2001 FRAMING Approved IVRS - Inspection 0000*
11/05/2001 FRAMING Denied IVRS - Inspection 0999*1.) STRAPS & HANGERS ARE DESIGNED TO BE USED WITH TICO (HANGER) NAILS. REMOVE DRYWALL NAILS IN POST CAPS AND USE HANGER NAILS. 2.)INSTALL HANGER NAILSIN ALL HOLES IN POST BASES 3.) INSTALL HANGER NAILS IN ALL LEDGER HANGERS @ RAFTERS. 4.) REVISE YOUR PLANS FOR AS BUILT AND HAVE THEM APPROVED BY THE CITY. 5.) INCLUDE ON REVISED PLAN YOUR LEDGER ATTACHMENT TO EXISTING HOUSE.