Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
| Date |
Description |
Inspector |
Results |
Comments |
| 01/23/2002 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Approved |
IVRS - Inspection 0000* |
| 01/18/2002 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Denied |
IVRS - Inspection 0999*1.) FOOTERS TO BE CAST AGAINST UNDISTURBED EARTH. YOU HAVE O REMOVE LOOSE BOTTOM FILL OR COMPACT TO 90% DENSITY 2.) FOOTING WIDTH ON WEST SIDE MUST BE 2'8" WIDE 32" PER PLAN. YOU ONLY HAVE 24" 3.) PLEASE PROVIDE RETAINING WALL DETAIL. |
| 09/25/2001 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Denied |
IVRS - Inspection 0999*1.) #4 VERTICAL REBAR REQUIRED EVERY 24" 2.) USE #5 HORIZONTAL REINFORCEMENT @ CENTER IN FOOTER. |