Inspection Status: Approved
Inspection History: POOL/SPA FINAL/BARRIER
| Date |
Description |
Inspector |
Results |
Comments |
| 06/01/2001 |
POOL/SPA FINAL/BARRIER |
|
Approved |
IVRS - Inspection 0000* |
| 05/31/2001 |
POOL/SPA FINAL/BARRIER |
|
Denied |
IVRS - Inspection 0999*/ 1) EXCESS OF 4" EXISTS BETWEEN FENCE VERTICAL BARS AT POSTS 4" MINIMUM ALLOWED 2) 4" MAXIMUM CLEARANCE EXCEEDED BETWEEN BOTTOM FENCE RAIL AND GROUND 3) POOL GATES MUST OPEN AWAY FROM POOL 4) PROVIDE PROOF OF POOL PLUMBING AND ELECTRIC INSPETION OR EXPOSE ALL OUTSIDE OF POOL PLUMBING AND ELECTRIC 5) 70 AMP ELECTRIC SERVICE APPREARS TO SMALL FOR LOAD, PROVIDE CITY OF TUCSON APPROVED LOAD CALCULATIONS FOR SERVICE PANEL |