Inspection History Details
Inspection Status: Approved
Inspection History: POOL/SPA ELECTRIC
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/15/2001 | POOL/SPA ELECTRIC | Approved | IVRS - Inspection 0000* | |
| 05/14/2001 | POOL/SPA ELECTRIC | Partial Approval | IVRS - Inspection 0000* 1) VERIFY POOL EQUIPMENT BONDING BACK TO SERVICE 2) CONDUITS TO BE BURIED ACCORDING TO NEC 300-5 | |
| 05/10/2001 | POOL/SPA ELECTRIC | Denied | IVRS - Inspection 0999* 1) SUPPORT CONDUITS BELOW JUNCTION BOX AND PANEL AS PER CODE 2) BOND JUNCTION BOX ENCLOSURE 250-96 3) FINISH CONNECTIONS AT TIME CLOCK 4) NEED LOCKNUTS OR BONDING DEVICE AT CHASE NIPPLE 5) VERIFY EQUIPMENT BONDS 6) FINISH SERVICE PANEL AND ADDRESS APNEL 7) CONDUITS TO BE ACCORDING TO CODE DEPTHS 300-5 8) LOOSE SEAL TITE FITTINGS |
|
| 04/18/2001 | POOL/SPA ELECTRIC | Partial Approval | IVRS - Inspection 0000* PK PVC UNDER COOL DECK, OK CONDUIT STUBS TO JUNCTION BOX, OK SCHEDULE 80 EQUIPMENT ROOM | |
| 04/12/2001 | POOL/SPA ELECTRIC | Partial Approval | IVRS - Inspection 0000* 1) PVC CONDUIT TO BE BURIED AS PER CODE DEPTHS 300-5 2) PVC IN EQUIPMENT ROOM TO BE SCH 80 ABOVE GROUND 3) NEED TO CHECK DEPTH OF SERVICE FEEDER CONDUIT |
|
| 03/15/2001 | POOL/SPA ELECTRIC | Partial Approval | IVRS - Inspection 0000* OK TO GUNITE. 1) NEED TO SEE CONNECTIONS PVC TO BRASS 2) NEED TO SEE ALL PVC AS INSTALLED |