Case: T00VL00340

Parcel: 108213300


Addresses:

4545 N VIA ENTRADA


Inspection Status: Correction Required

Inspection History: INITIAL CODE VIOLATION

Case Number - T00VL00340

Inspection Description - INITIAL CODE VIOLATION

Inspection Status - Correction Required

Date Description Inspector Results Comments
03/22/2000 INITIAL CODE VIOLATION Correction Required ADDTL COMMS - FIRST FLOOR APT. GIRDER BETWEEN 1ST AND 2ND FLOORS HAS TWISTED, CAUSING A HORIZONTAL CRACK, WHICH ALLOWS WATER PENETRATION. APPEARS TO HAVE BEEN LEAKING A LONG TIME. BOTTOM SECTIONS OF SHEETROCK REMOVED FROM THIS SOUTH WALL. VISIBLE STUDS AND BOTTOM PLATE ARE ROTTED. SCREW DRIVER WENT RIGHT THROUGH SEVERAL STUDS AND SEVERAL AREAS OF THE BOTTOM PLATE. PROP MAN WAS TOLD TO REPLACE THE WALL AND OBTAIN PERMIT. PROP MAN SAID WALL WILL BE REPLACED AFTER THE TENANTS MOVE OUT THIS WEEK. CHECK BACK 4/7
03/22/2000 INITIAL CODE VIOLATION Violation VIOLATION