Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T00PL02142

Parcel: 14027069A


Addresses:

2707 E VALENCIA RD

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
11/20/2000 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection 0000*
PRESSURE TEST OK
ILLEGAL VALVES REMOVED AND RIGHT/LEFT HAND NIPPLE AND COUPLING INSTALLED
REAR HEATER VALVE OK
OK FOR GAS
11/14/2000 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0999*
NO PRESSURE TEST NEED 10 LBS FOR 15 MINUTES MINIMUM
ALL VALVES MUST HAVE AGA OR CSA STAMP IN
VALVE BODY
AT METER BRANCH TO REAR BLDG
JUST INSIDE REAR BLDG LOW AT HEATER IN REAR BLDG
JUST INSIDE REAR BLDG LOW
AT HEATER ON REAR BLDG