Permit: T00PL01863

Parcel: 112033110


Addresses:

2520 E HALCYON RD

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
10/19/2000 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection 0000*
GAS PRESSURE TEST OK
GAS SHUT OFF VALVES OK
WATER HEATER FLU VENT, P&T DRAIN OK
FURNACE FLU VENT OK
OK TO BACKFILL TRENCH
10/18/2000 PLUMBING - GAS PRESSURE TEST Denied WATER HEATER MUST HAVE PRESSURE RE LITE VALVE AND DRAIN TO DAYLIGHT
GAS LINE CAN NOT HAVE ANY UNION IN LINE MUST REPLACE WITH RIGHT AND LEFT HAND NIPPLES ON ROOF
GAS LINE IS UNDERSIZED FROM METER TO HOUSE. GAS LINE FOR CFH DEMAND MUST BE MIN 1" FROM METER TO HOUSE SERVICE
FLU VENT FOR WATER HEATER AND FURNACE MUST TERMINATE 1'-10" ABOVE COOLER