Permit: T00PL01851

Parcel: 133061480


Addresses:

8900 E CALLE KUEHN

Inspection Status: Approved

Inspection History: PLUMBING - GAS PRESSURE TEST

Date Description Inspector Results Comments
10/11/2000 PLUMBING - GAS PRESSURE TEST Approved IVRS - Inspection 0000*
WATER HEATER P&T DRAIN OK
ALL CORRECTION HAVE BEEN MADE
10/10/2000 PLUMBING - GAS PRESSURE TEST Denied IVRS - Inspection 0999*
P&T DRAIN MUST HAVE UNION IN LINE
CAN NOT CONNECT COPPER TO GALV MUST USE DI ELECTRIC UNION OR BRASS NIPPLE
10/09/2000 PLUMBING - GAS PRESSURE TEST Partial Approval IVRS - Inspection 0000*
GAS FLEX TO FURNACE CANNOT PENETRATE THE FURNACE HOUSING
COPPER FLEX ON T&P VALVE ON WATER HEATER CANNOT EXCEED 12"
GAS PRESSURE TEST OK
MAKE NECESSARY CORRECTIONS AND RECALL FOR INSPECTION