Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - GAS PRESSURE TEST
Permit Number - T00PL01800
Inspection Description - PLUMBING - GAS PRESSURE TEST
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/04/2000 | PLUMBING - GAS PRESSURE TEST | Approved | IVRS - Inspection 0000* 1. GAS PRESSURE TEST OK 2. GAS SHUT OFF VALVES OK 3. WATER HEATER P&T DRAIN FLU VENT OK 4. WALL FURNACE FLU VENT OK 5. ALL CORRECTIONS HAVE BEEN MADE |
|
| 10/03/2000 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection 0999* MUST HAVE SHUT OFF VALVE BEFORE UNION AT BLDG SERVICE MUST HAVE AGA APPROVED GS SHUT OFF VALVES AT ALL APPLIANCES WATER HTR FLU VENT MUST BE SCREWED DOWN WITH SHEET METAL SCREWS WATER HTR DBL WALL FLU VENT MUST HAVE MIN 1" CLEARANCE AROUND VENT WATER HTR P&T DRAIN MUST HAVE UNION AND RUN TO DAYLIGHT RE TEST SYSTEM 10 LBS MIN |
|
| 10/02/2000 | PLUMBING - GAS PRESSURE TEST | Denied | IVRS - Inspection 0999* MUST HAVE ACCESS TO ALL GAS APPLIANCES INSIDE DWELLING |