Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - PROGRESS
Permit Number - T00PL01752
Inspection Description - PLUMBING - PROGRESS
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/31/2001 | PLUMBING - PROGRESS | Approved | IVRS - Inspection 0000* | |
| 05/30/2001 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection 0000*1)AIR PRESSURE TEST OK FOR MH #6,9,10 AND MH #7,7-A ONLY. | |
| 05/22/2001 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection 0000*1)MAN HOLE INSTALLION FOR SITE SEWER #6,7,8,9,10 OK.2)OK TO BACK FILL TRENCH. | |
| 05/15/2001 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection 0000* 1) SITE SEWER OK FROM MH #6 TO MH #9 AND MH #10 ALL THE WAY TO BLDG #26 2) OK TO BACK FILL TRENCH | |
| 05/11/2001 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection 0000* 1) SITE TO SEWER OK FROM M.H. #7, 7-A, AND 8 2) OK TO BACKFILL | |
| 05/08/2001 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection 0000* 1) AIR PRESSURE TEST FROM M.H. #3, 4, 5 OK | |
| 04/30/2001 | PLUMBING - PROGRESS | Not ready for Inspection | IVRS - Inspection 0000* NOT READY | |
| 04/26/2001 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection 0000*1) AIR TEST FROM EXSISTING MANHOLE AT ASHTON MEDOWS APTS TO MANHOLE #2(LOST A 1/2 LB IN 5 MINUTES) 2) AIR TEST FROM MANHOLE #2 TO MANHOLE #3 LOST 2/10LB IN FIVE MINUTES. 3) AIR TEST FROM MANHOLE #3 TO MANHOLE #4 LOST OVER 1 LB IN FIVE MINUTES 4) AIR TEST FROM MANHOLE #4 TO MANHOLE #5 NOT READY 5) AIR TEST FROM MANHOLE #5 TO MANHOLE #6 NOT READY |
|
| 04/25/2001 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection 0000* 1) SITE SEWER INSTALLATION OK FOR BLDG #1-#11 AND REC BLDG 2) OK TO BACKFILL |
|
| 04/24/2001 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection 0000* 1) SITE SEWER OK UP TO BLDG#3&4, 8-11, 14, 27, AND MH 1-6 OK FOR BACKFILL | |
| 04/20/2001 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection 0000* 1) SITE SEWER OK FROM M.H. #2 EAST TO M.H. AT BLDG #1 2) SITE SEWER OK FOR BLDG #9 3) OK TO BACKFILL TRENCH | |
| 04/19/2001 | PLUMBING - PROGRESS | Not ready for Inspection | IVRS - Inspection 0000* NOT READY | |
| 04/18/2001 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection 0000* 1) SITE SEWER 8" OK UP TO MH #6 2) OK TO BACKFILL TRENCH | |
| 04/17/2001 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection 0000*1. 8" SITE SEWER FROM STAKE # 3+75 TO # 1+00 OK TO BACKFILL TRENCH 2. NOTE OK TO BACKFILL MANHOLE # 2 | |
| 04/16/2001 | PLUMBING - PROGRESS | Not ready for Inspection | IVRS - Inspection 0000* | |
| 04/13/2001 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection 0000* 1) SITE SEWER OK UP TO STAKE #3+75 2) OK TO BACKFILL | |
| 04/12/2001 | PLUMBING - PROGRESS | Partial Approval | IVRS - Inspection 0000* 1) SITE SEWER (8") OK FROM M.H. #2 TO STAKE #2+25 OK 2) OK TO BACKFILL TRENCH UP TO THIS POINT 3) PROVIDE AIR OR WATER TEST AT LATER TIME | |
| 04/10/2001 | PLUMBING - PROGRESS | Not ready for Inspection | NOT READY BETWEEN M-H #1 AND M-H #2 | |
| 04/09/2001 | PLUMBING - PROGRESS | Not ready for Inspection | IVRS - Inspection 0000* 1) INSP. 9:00AM NOT READY 2) INSP. FROM MH #1 TO MH#2 |